{"title":"USG5000M Options","description":"","products":[{"product_id":"usg5000m-pm","title":"USG5000M-PM","description":"\u003ch1\u003eUNI-T USG5000M-PM Pulse Modulation Option\u003c\/h1\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PM pulse modulation option adds advanced pulse modulation capabilities to the USG5000M series microwave signal generators. This high-performance option enables precise generation of pulsed RF signals across the extended frequency ranges of the USG5000M series, making it ideal for sophisticated radar system development, satellite communications testing, and millimeter-wave applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior On-Off Ratio\u003c\/strong\u003e: Up to 80 dB (≤ 6.5 GHz) and 70 dB (≤ 22 GHz) for clean pulse definition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Transition Times\u003c\/strong\u003e: Rising\/falling times \u0026lt; 20 ns for accurate edge definition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Operating Modes\u003c\/strong\u003e: Free-run, square, external triggered, adjustable doublet, gated, and custom pulse train modes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Pulse Sequences\u003c\/strong\u003e: Create complex pulse patterns with user-defined timing parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Coverage\u003c\/strong\u003e: Full pulse modulation across the entire frequency range of the generator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Triggering\u003c\/strong\u003e: Internal, external, or bus-triggered operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Off Ratio\u003c\/td\u003e\n\u003ctd\u003e≥ 80 dBc (typical) for frequencies ≤ 6.5 GHz\u003cbr\u003e≥ 70 dBc (typical) for frequencies ≤ 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRising\/Falling Time (10%\/90%)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 20 ns (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd\u003e100 μs to (Pulse period -1 μs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Period\u003c\/td\u003e\n\u003ctd\u003ePulse width +1 μs to 42 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 μs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Delay\u003c\/td\u003e\n\u003ctd\u003eFree-run: 0 to (Period – Pulse width -1 μs)\u003cbr\u003eTrigger: 1 μs to (Maximum pulse period-1 μs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; ± 0.5 dB (Relative to CW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth Compression\u003c\/td\u003e\n\u003ctd\u003e≤ 10 ns (Relative to RF width of pulse output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo Feed-through\u003c\/td\u003e\n\u003ctd\u003e≤ 50 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Pulse Input Delay\u003c\/td\u003e\n\u003ctd\u003e500 ns (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Delay\u003c\/td\u003e\n\u003ctd\u003e50 ns (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Overshoot\u003c\/td\u003e\n\u003ctd\u003e≤ 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplication Examples\u003c\/h2\u003e\n\u003ch3\u003eAdvanced Radar Development\u003c\/h3\u003e\n\u003cp\u003eSupport cutting-edge radar system testing with precise pulse control:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate complex pulse patterns for modern phased array radar development\u003c\/li\u003e\n\u003cli\u003eTest radar receiver sensitivity with controlled pulse widths and repetition rates\u003c\/li\u003e\n\u003cli\u003eValidate advanced radar signal processing with precisely defined pulse characteristics\u003c\/li\u003e\n\u003cli\u003eSimulate multi-target environments with customized pulse trains\u003c\/li\u003e\n\u003cli\u003eVerify radar performance across extended microwave and millimeter-wave bands\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSatellite Communications Testing\u003c\/h3\u003e\n\u003cp\u003eEvaluate satellite communications equipment with accurate pulsed signals:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest transponder performance with precisely controlled pulse characteristics\u003c\/li\u003e\n\u003cli\u003eVerify ground station receiver sensitivity using pulsed signals\u003c\/li\u003e\n\u003cli\u003eSimulate burst transmissions for time-division multiple access systems\u003c\/li\u003e\n\u003cli\u003eCharacterize satellite receiver performance across Ku, K, and Ka bands\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMillimeter-Wave System Development\u003c\/h3\u003e\n\u003cp\u003eSupport pre-5G and 5G millimeter-wave system development:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate pulsed signals for 5G FR2 component characterization\u003c\/li\u003e\n\u003cli\u003eTest receiver performance under pulsed interference conditions\u003c\/li\u003e\n\u003cli\u003eCharacterize power amplifiers under pulsed conditions\u003c\/li\u003e\n\u003cli\u003eEvaluate beam-forming network performance with pulsed excitation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectronic Warfare Systems\u003c\/h3\u003e\n\u003cp\u003eSupport electronic warfare applications with sophisticated pulse control:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCreate complex pulse patterns for radar warning receivers\u003c\/li\u003e\n\u003cli\u003eSimulate target returns for missile guidance systems\u003c\/li\u003e\n\u003cli\u003eTest electronic countermeasure effectiveness\u003c\/li\u003e\n\u003cli\u003eEvaluate direction finding systems with pulsed signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIntegration with USG5000M Series\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PM option works with all models in the USG5000M series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M (9 kHz to 14 GHz)\u003c\/li\u003e\n\u003cli\u003eUSG5014M-P (9 kHz to 14 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003cli\u003eUSG5022M-P (9 kHz to 22 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe pulse modulation functions are seamlessly integrated into the generator's user interface, with dedicated controls for all pulse parameters accessible through the front panel and remote interfaces.\u003c\/p\u003e\n\u003ch2\u003eCompatibility with Other Options\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PM pulse modulation option works in conjunction with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5000M-PG narrow pulse generator option for ultra-narrow pulse generation\u003c\/li\u003e\n\u003cli\u003eUSG5000M-PK power meter kit for accurate power control during pulse modulation\u003c\/li\u003e\n\u003cli\u003eUSG5000M-GPIB interface for remote control of pulse parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eOrder Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Modulation Option for USG5000M Series\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor enhanced narrow pulse capabilities down to 20 ns, the USG5000M-PG option is recommended as an additional upgrade.\u003c\/p\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PM option can be installed at the time of purchase or added later as an upgrade. For existing units, the option is enabled through a license file installation procedure that can be performed by the user.\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103322472732,"sku":"191502400021","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5000M-PM.png?v=1741127018"},{"product_id":"usg5000m-pg","title":"USG5000M-PG","description":"\u003ch1\u003eUNI-T USG5000M-PG Narrow Pulse Generator Option\u003c\/h1\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PG narrow pulse generator option enhances the USG5000M series microwave signal generators with ultra-narrow pulse generation capabilities. This specialized option enables the creation of extremely short RF pulses with precise timing control, essential for advanced radar systems, automotive millimeter-wave radar development, and high-speed digital communications testing at microwave frequencies.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Narrow Pulse Generation\u003c\/strong\u003e: Create pulses as narrow as 20 ns with 10 ns resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Timing Control\u003c\/strong\u003e: Set pulse parameters with 10 ns timing resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Frequency Coverage\u003c\/strong\u003e: Generate narrow pulses across the full frequency range up to 22 GHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Pulse Period\u003c\/strong\u003e: Configure pulse periods from 40 ns to 42 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Triggering Options\u003c\/strong\u003e: Free-running or triggered operation for versatile test setups\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: Fully integrated with the standard user interface for intuitive operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd\u003e20 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Period\u003c\/td\u003e\n\u003ctd\u003e40 ns to 42 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Delay (Free-running)\u003c\/td\u003e\n\u003ctd\u003e0 to (Period – Pulse width -20 ns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Delay (Triggered)\u003c\/td\u003e\n\u003ctd\u003e20 ns to (Maximum pulse period -20 ns)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Off Ratio\u003c\/td\u003e\n\u003ctd\u003eIn conjunction with USG5000M-PM:\u003cbr\u003e≥ 80 dB (≤ 6.5 GHz)\u003cbr\u003e≥ 70 dB (≤ 22 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise\/Fall Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 20 ns (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplication Examples\u003c\/h2\u003e\n\u003ch3\u003eAutomotive Millimeter-Wave Radar Testing\u003c\/h3\u003e\n\u003cp\u003eSupport advanced automotive radar development with precise pulse control:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate narrow pulses for 77 GHz and 79 GHz automotive radar testing\u003c\/li\u003e\n\u003cli\u003eSimulate target returns with precise timing characteristics\u003c\/li\u003e\n\u003cli\u003eTest radar receiver sensitivity with controlled narrow pulses\u003c\/li\u003e\n\u003cli\u003eValidate collision avoidance radar systems with precise pulse sequences\u003c\/li\u003e\n\u003cli\u003eCharacterize automotive radar components across temperature ranges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh-Frequency Communications Testing\u003c\/h3\u003e\n\u003cp\u003eEvaluate cutting-edge communications systems:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest pulse recovery in high-speed microwave receivers\u003c\/li\u003e\n\u003cli\u003eCharacterize timing margins in broadband communications systems\u003c\/li\u003e\n\u003cli\u003eEvaluate jitter performance with precisely controlled pulse timing\u003c\/li\u003e\n\u003cli\u003eTest recovery time of communication system components\u003c\/li\u003e\n\u003cli\u003eSimulate burst transmissions in time-division systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Aerospace and Defense Applications\u003c\/h3\u003e\n\u003cp\u003eSupport sophisticated aerospace and defense testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate precise timing signals for phased array radar systems\u003c\/li\u003e\n\u003cli\u003eTest radar warning receivers with narrowly defined pulses\u003c\/li\u003e\n\u003cli\u003eSimulate electronic countermeasures with complex pulse patterns\u003c\/li\u003e\n\u003cli\u003eCharacterize guidance system components with precise timing control\u003c\/li\u003e\n\u003cli\u003eCreate realistic radar environments for system validation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eResearch and Advanced Development\u003c\/h3\u003e\n\u003cp\u003eEnable cutting-edge research applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport terahertz technology development with precisely defined pulses\u003c\/li\u003e\n\u003cli\u003eCreate timing references for synchronizing multiple test instruments\u003c\/li\u003e\n\u003cli\u003eGenerate stimulus signals for high-speed digital circuit testing\u003c\/li\u003e\n\u003cli\u003eSupport quantum communications research with precise timing control\u003c\/li\u003e\n\u003cli\u003eEnable sophisticated time-domain measurements in microwave circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIntegration Requirements\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PG option requires the USG5000M-PM pulse modulation option to be installed first. Together, these options provide comprehensive pulse generation capabilities from standard to ultra-narrow pulse widths across the full frequency range of the USG5000M series.\u003c\/p\u003e\n\u003cp\u003eThe USG5000M-PG option can be installed on any model in the USG5000M series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M (9 kHz to 14 GHz)\u003c\/li\u003e\n\u003cli\u003eUSG5014M-P (9 kHz to 14 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003cli\u003eUSG5022M-P (9 kHz to 22 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Advantages for Test and Measurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Radar Testing\u003c\/strong\u003e: Simulate modern radar systems with shorter pulses and higher PRFs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Resolution\u003c\/strong\u003e: 10 ns resolution provides finer control than standard pulse generators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Frequency Coverage\u003c\/strong\u003e: Generate narrow pulses across microwave and millimeter-wave frequencies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive Radar Development\u003c\/strong\u003e: Support development of collision avoidance and adaptive cruise control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Applications\u003c\/strong\u003e: Enable advanced time-domain measurements at microwave frequencies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eOrder Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNarrow Pulse Generator Option for USG5000M Series\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Pulse Modulation Option\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eBoth options must be specified to achieve full narrow pulse generation capabilities.\u003c\/p\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PG option can be installed at the time of purchase or added later as an upgrade. For existing units, the option is enabled through a license file installation procedure that can be performed by the user after installing the USG5000M-PM option.\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103322734876,"sku":"191502400019","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5000M-PG.png?v=1741127018"},{"product_id":"usg5000m-pk","title":"USG5000M-PK","description":"\u003ch1\u003eUNI-T USG5000M-PK Power Meter Option\u003c\/h1\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PK Power Meter Option is a precision measurement accessory for the USG5000M series microwave signal generators. This integrated solution provides accurate RF and microwave power measurement, output power control, and line loss calibration across the full frequency range of the generators. The USG5000M-PK ensures that the exact power level reaches your device under test, critical for high-frequency applications where cable and connector losses can significantly impact measurement accuracy.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Frequency Coverage\u003c\/strong\u003e: Measure power across the full frequency range of the USG5000M series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Power Measurement\u003c\/strong\u003e: Directly measure RF power at the device under test with high accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Output Control\u003c\/strong\u003e: Set the desired power at the test point and let the system compensate for all losses\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Loss Calibration\u003c\/strong\u003e: Create comprehensive loss profiles across frequency to ensure accurate power delivery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeamless Integration\u003c\/strong\u003e: Connect directly to the front panel USB port for plug-and-play operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Operation\u003c\/strong\u003e: Intuitive controls through the signal generator's user interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e10 MHz to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-35 dBm to +20 dBm (frequency dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Measurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 dB (typical) up to 18 GHz\u003cbr\u003e±0.7 dB (typical) up to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 14 dB (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 (compatible with SMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.5 meters (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB (connects to front panel USB port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplication Examples\u003c\/h2\u003e\n\u003ch3\u003eMillimeter-Wave System Development\u003c\/h3\u003e\n\u003cp\u003eEnsure accurate power delivery in high-frequency applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompensate for significant cable losses at microwave frequencies\u003c\/li\u003e\n\u003cli\u003eEnsure precise power levels for 5G FR2 component testing\u003c\/li\u003e\n\u003cli\u003eMaintain consistent power levels during frequency sweeps up to 22 GHz\u003c\/li\u003e\n\u003cli\u003eCalibrate test setups for satellite communications in Ku, K, and Ka bands\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMicrowave Component Characterization\u003c\/h3\u003e\n\u003cp\u003eImprove measurement accuracy in component testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrecisely control input power for amplifier gain and linearity measurements\u003c\/li\u003e\n\u003cli\u003eMaintain exact power levels for mixer conversion loss testing\u003c\/li\u003e\n\u003cli\u003eEnsure accurate stimulus levels for filter response characterization\u003c\/li\u003e\n\u003cli\u003eCompensate for temperature-dependent cable losses during environmental testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduction Testing of High-Frequency Devices\u003c\/h3\u003e\n\u003cp\u003eEnhance manufacturing test efficiency and accuracy:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure consistent power levels reach each device under test\u003c\/li\u003e\n\u003cli\u003eAutomatically compensate for test fixture and cable variations between test stations\u003c\/li\u003e\n\u003cli\u003eCreate frequency-dependent compensation tables for complex test setups\u003c\/li\u003e\n\u003cli\u003eMaintain calibrated power levels throughout extended production runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eResearch and Development\u003c\/h3\u003e\n\u003cp\u003eSupport precise laboratory measurements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvide accurate power control for sensitive experiments\u003c\/li\u003e\n\u003cli\u003eDocument actual power levels at the device under test\u003c\/li\u003e\n\u003cli\u003eEliminate uncertainty from cable and connector losses\u003c\/li\u003e\n\u003cli\u003eMaintain experiment repeatability through precise power calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIntegration with USG5000M Series\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-PK power meter kit works with all models in the USG5000M series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M (9 kHz to 14 GHz)\u003c\/li\u003e\n\u003cli\u003eUSG5014M-P (9 kHz to 14 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003cli\u003eUSG5022M-P (9 kHz to 22 GHz with mechanical attenuator)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe power meter functions are seamlessly integrated into the generator's user interface, with dedicated menus for measurement, calibration, and power control functions.\u003c\/p\u003e\n\u003ch2\u003eKey Advantages at Microwave\u003c\/h2\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103322931484,"sku":"191502400018","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5000M-PK.png?v=1741127018"},{"product_id":"usg5000m-gpib","title":"USG5000M-GPIB","description":"\u003ch1\u003eUNI-T USG5000M-GPIB RF Signal Generator\u003c\/h1\u003e\n\u003ch2\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T USG5000M-GPIB option adds comprehensive GPIB connectivity to the USG5000M Series RF Signal Generator, enabling seamless integration with automated test systems. This IEEE-488.2 compliant interface provides full remote control capabilities with SCPI command compatibility, making it ideal for production testing environments.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEEE-488.2 Compliant Interface\u003c\/strong\u003e for complete automated test integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull SCPI Command Set Support\u003c\/strong\u003e for easy programming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Command Response Time\u003c\/strong\u003e of less than 2ms for efficient test execution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Status Reporting\u003c\/strong\u003e for reliable operation in production environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible with Industry-Standard Test Software\u003c\/strong\u003e including LabVIEW and MATLAB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperates Alongside USB and LAN Interfaces\u003c\/strong\u003e for flexible connectivity options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUNI-T USG5000M-GPIB Details\u003c\/h2\u003e\n\u003cp\u003eThe GPIB interface option enables remote control of all instrument functions, including frequency and amplitude settings, modulation parameters, and sweep configurations. The quick response time of less than 2ms ensures efficient test execution even in complex test sequences. Built-in status reporting and error handling capabilities provide robust operation in production environments where reliability is paramount.\u003c\/p\u003e\n\u003cp\u003eThe USG5000M-GPIB interface works alongside the standard USB and LAN interfaces, offering maximum flexibility for integration into various test systems. It supports standard SCPI command sets, simplifying integration with existing test systems and reducing development time for new automated test applications.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003ch3\u003eProduction Testing\u003c\/h3\u003e\n\u003cp\u003eManufacturing environments benefit from the USG5000M-GPIB's seamless integration into automated test systems. The instrument's reliability, repeatability, and high-speed command processing contribute to efficient production testing with minimal test time per unit.\u003c\/p\u003e\n\u003ch3\u003eResearch \u0026amp; Development\u003c\/h3\u003e\n\u003cp\u003eR\u0026amp;D engineers can automate complex measurement sequences for consistent, repeatable results when characterizing new devices or systems. The GPIB interface enables programmatic control of all signal parameters for comprehensive test coverage.\u003c\/p\u003e\n\u003ch3\u003eEducation and Training\u003c\/h3\u003e\n\u003cp\u003eTechnical universities can use the GPIB interface to teach automated test principles and RF measurement techniques, preparing students for industry-standard practices.\u003c\/p\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThe USG5000M-GPIB option can be ordered with a new USG5000M Series RF Signal Generator or added to an existing instrument. For existing instruments, installation must be performed by an authorized UNI-T service center.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE-488.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e24-pin GPIB connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand Language\u003c\/td\u003e\n\u003ctd\u003eSCPI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress Range\u003c\/td\u003e\n\u003ctd\u003e0-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatible Instruments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M Series RF Signal Generator\u003c\/li\u003e\n\u003cli\u003eUSG5022M Series RF Signal Generator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGPIB Interface Module\u003c\/li\u003e\n\u003cli\u003eInstallation Certificate\u003c\/li\u003e\n\u003cli\u003eGPIB Programming Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003eOrder Number: USG5000M-GPIB\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The GPIB option can be ordered with a new instrument or as an upgrade to an existing instrument. For upgrades, please provide your instrument's serial number when ordering.\u003c\/em\u003e\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103323095324,"sku":"191502400022","price":559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5000M-GPIB.png?v=1741127018"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/collections\/USG5000M_Options.png?v=1741127910","url":"https:\/\/uni-trendus.com\/collections\/usg5000-options.oembed","provider":"Uni-Trend US","version":"1.0","type":"link"}