{"title":"USG5000M","description":"\u003ch1\u003eRF Signal Generator Buying Guide\u003c\/h1\u003e\n\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eRadio Frequency (RF) signal generators are essential tools for professionals working in wireless communications, aerospace, defense, semiconductor testing, and research and development. These precision instruments produce controlled RF signals with specific characteristics that are vital for testing, troubleshooting, and calibrating RF systems and components. This guide will help you understand the key considerations when selecting an RF signal generator to ensure you choose the right instrument for your specific applications.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications to Consider\u003c\/h2\u003e\n\u003ch3\u003eFrequency Range\u003c\/h3\u003e\n\u003cp\u003eThe frequency range is perhaps the most critical specification to consider when selecting an RF signal generator.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication-specific requirements\u003c\/strong\u003e: Your required frequency range depends entirely on the application. For example:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMobile communications: 700 MHz - 6 GHz\u003c\/li\u003e\n\u003cli\u003eWi-Fi testing: 2.4 GHz and 5 GHz bands\u003c\/li\u003e\n\u003cli\u003eAutomotive radar: 24 GHz, 77 GHz, 79 GHz\u003c\/li\u003e\n\u003cli\u003eSatellite communications: Various bands up to 50 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuture-proofing\u003c\/strong\u003e: Consider selecting a generator with a frequency range that extends beyond your current needs to accommodate future applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: Look for generators with fine frequency resolution (e.g., 0.001 Hz) for precise testing requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAttenuator Type: Mechanical vs. Electronic\u003c\/h3\u003e\n\u003cp\u003eThe type of attenuator used in an RF signal generator significantly impacts its performance characteristics and suitability for different applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Attenuators\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior level stability\u003c\/strong\u003e: Provides more consistent output power, especially over long testing periods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigher maximum output power\u003c\/strong\u003e: Typically delivers higher output levels for driving power-hungry devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetter VSWR performance\u003c\/strong\u003e: Offers improved impedance matching across frequency ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced durability\u003c\/strong\u003e: Less susceptible to damage from excessive input power\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal applications\u003c\/strong\u003e: Production testing, power amplifier characterization, receiver sensitivity testing, applications requiring higher output power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Attenuators\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster switching speed\u003c\/strong\u003e: Allows for rapid level changes in automated test sequences\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo moving parts\u003c\/strong\u003e: Generally more suitable for applications requiring frequent level changes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiner resolution\u003c\/strong\u003e: Often provides more precise level control in small increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal applications\u003c\/strong\u003e: High-speed automated testing, scenarios requiring frequent level adjustments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderations when choosing\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor applications requiring maximum output power and stability, a mechanical attenuator is preferable\u003c\/li\u003e\n\u003cli\u003eFor applications requiring rapid level changes, an electronic attenuator may be more suitable\u003c\/li\u003e\n\u003cli\u003ePremium instruments often offer models with either option to accommodate different testing needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOutput Power Range\u003c\/h3\u003e\n\u003cp\u003eThe output power range determines the signal generator's ability to simulate both strong and weak signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDynamic range\u003c\/strong\u003e: A wide dynamic range (e.g., -135 dBm to +25 dBm) provides more testing flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum output power\u003c\/strong\u003e: Higher maximum output power is useful when testing receiver sensitivity or driving power amplifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum output power\u003c\/strong\u003e: Low output levels are essential for testing receiver sensitivity thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Purity\u003c\/h3\u003e\n\u003cp\u003eSignal purity affects the accuracy and reliability of your measurements and is critical for many applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase noise\u003c\/strong\u003e: Lower phase noise is critical for testing high-performance receivers and radar systems. Look for specifications like \u0026lt;-122 dBc\/Hz at specific offsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarmonics\u003c\/strong\u003e: Lower harmonic content ensures your test signals don't introduce unwanted frequency components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-harmonics\u003c\/strong\u003e: Spurious signals can affect measurement accuracy, so lower non-harmonic levels are desirable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eModulation Capabilities\u003c\/h3\u003e\n\u003cp\u003eModern RF signal generators typically offer various modulation options to simulate real-world signals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog modulation\u003c\/strong\u003e: Basic capabilities include AM, FM, and ΦM (phase modulation).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse modulation\u003c\/strong\u003e: Important for radar testing and pulsed communication systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital modulation\u003c\/strong\u003e: Some applications may require generators with digital modulation capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustom modulation\u003c\/strong\u003e: Consider whether you need to create custom modulation schemes or if standard modulations are sufficient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAmplitude Accuracy\u003c\/h3\u003e\n\u003cp\u003eAmplitude accuracy is vital for reliable measurements, especially when testing receiver sensitivity or transmitter power levels.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLook for specifications\u003c\/strong\u003e: Typically expressed in dB, lower values indicate better accuracy (e.g., ≤ 0.7 dB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsider temperature range\u003c\/strong\u003e: Accuracy specifications are usually given for a specific temperature range, so consider your operating environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdditional Features and Considerations\u003c\/h2\u003e\n\u003ch3\u003eSweep Capabilities\u003c\/h3\u003e\n\u003cp\u003eSweep functionality allows the generator to automatically step through frequencies or power levels, which is useful for characterizing frequency-dependent behavior.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSweep types\u003c\/strong\u003e: Look for frequency, amplitude, and list sweep capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSweep parameters\u003c\/strong\u003e: Consider the range of step sizes, dwell times, and triggering options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInternal Function Generator\u003c\/h3\u003e\n\u003cp\u003eMany RF signal generators include built-in function generators that can be useful for creating modulating signals or for general-purpose testing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency range\u003c\/strong\u003e: Typically up to 50 MHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWaveform types\u003c\/strong\u003e: Common waveforms include sine, square, triangle, ramp, and arbitrary waveforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConnectivity and Control\u003c\/h3\u003e\n\u003cp\u003eModern test equipment typically offers multiple connectivity options for integration into automated test systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical interfaces\u003c\/strong\u003e: Common options include LAN, USB, and GPIB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote control\u003c\/strong\u003e: Consider the availability of drivers and command sets for your programming environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser interface\u003c\/strong\u003e: Evaluate the ease of use of the front panel controls and display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize and Form Factor\u003c\/h3\u003e\n\u003cp\u003eThe physical dimensions of the instrument may be important depending on your workspace constraints.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBench-top vs. rack-mount\u003c\/strong\u003e: Consider whether the instrument will be used in a fixed location or needs to be rack-mounted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePortability\u003c\/strong\u003e: If you need to move the generator between locations, weight and size become more important.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReliability and Support\u003c\/h3\u003e\n\u003cp\u003eInvesting in a quality instrument from a reputable manufacturer ensures long-term reliability and available support.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration interval\u003c\/strong\u003e: Typically one year for professional instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e: Most quality instruments come with at least a one-year warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eService and support\u003c\/strong\u003e: Consider the availability of technical support and repair services.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplication-Specific Considerations\u003c\/h2\u003e\n\u003ch3\u003eWireless Communications Testing\u003c\/h3\u003e\n\u003cp\u003eFor testing wireless devices and components, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency coverage\u003c\/strong\u003e: Must include the specific bands used by the technologies you're testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModulation schemes\u003c\/strong\u003e: Should support the modulation types used in your target wireless standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal purity\u003c\/strong\u003e: Clean signals are essential for accurate receiver sensitivity measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAerospace and Defense\u003c\/h3\u003e\n\u003cp\u003eFor aerospace and defense applications, important considerations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency stability\u003c\/strong\u003e: Critical for radar and precision navigation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse modulation capabilities\u003c\/strong\u003e: Essential for radar testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase noise performance\u003c\/strong\u003e: Crucial for testing high-performance receivers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGeneral Research and Education\u003c\/h3\u003e\n\u003cp\u003eFor laboratory and educational use, consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatility\u003c\/strong\u003e: A wide range of features to support various experiments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEase of use\u003c\/strong\u003e: Intuitive interface for students and researchers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effectiveness\u003c\/strong\u003e: Balance between performance and budget constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCost Considerations\u003c\/h2\u003e\n\u003cp\u003eRF signal generators vary widely in price based on their specifications and capabilities.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance tiers\u003c\/strong\u003e: Higher frequency ranges, better signal purity, and more advanced modulation capabilities generally command higher prices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional features\u003c\/strong\u003e: Consider which features are essential now versus what might be added later as optional upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal cost of ownership\u003c\/strong\u003e: Include considerations for calibration, maintenance, and potential future upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConclusion\u003c\/h2\u003e\n\u003cp\u003eSelecting the right RF signal generator requires a thorough understanding of your current and future testing needs. By carefully considering the specifications and features outlined in this guide, you can make an informed decision that balances performance requirements with budget constraints.\u003c\/p\u003e\n\u003cp\u003eRemember that investing in a quality instrument from a reputable manufacturer like UNI-T ensures reliability, accuracy, and long-term support, making it a sound investment for your RF testing needs.\u003c\/p\u003e","products":[{"product_id":"usg5022m-p-analog-rf-gen-atten","title":"USG5022M-P 22GHz Analog RF Generator with Attenuator","description":"\u003ch1\u003eUNI-T USG5022M-P RF Signal Generator with Mechanical Attenuator\u003c\/h1\u003e\n\u003ch2\u003eUltimate Microwave\/Millimeter-Wave Signal Generation to 22 GHz with Superior Performance\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T USG5022M-P stands as the flagship of UNI-T's RF signal generator lineup, delivering exceptional performance from 9 kHz to 22 GHz with mechanical attenuation for premium output power and stability. This state-of-the-art instrument meets the exacting requirements of advanced wireless communications, aerospace and defense, satellite systems, and millimeter-wave research where extended frequency coverage and superior signal quality are non-negotiable.\u003c\/p\u003e\n\u003ch2\u003eSuperior Performance Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Attenuator System\u003c\/strong\u003e: Premium mechanical attenuation for unmatched output power stability and signal integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustry-Leading Frequency Range\u003c\/strong\u003e: Generate precision signals from 9 kHz to 22 GHz with 0.001 Hz resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Output Power Range\u003c\/strong\u003e: Deliver up to +23 dBm output (frequency dependent) with precise level control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutstanding Signal Purity\u003c\/strong\u003e: Ultra-low phase noise (\u0026lt;-122 dBc\/Hz @ 1 GHz, -98 dBc\/Hz @ 22 GHz) for sensitive testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExceptional Level Accuracy\u003c\/strong\u003e: ≤ 0.7 dB (typical) for reliable measurements across the frequency spectrum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Modulation Suite\u003c\/strong\u003e: Standard AM, FM, and ΦM with internal, external, or combined sources\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Sweep Capabilities\u003c\/strong\u003e: Frequency, amplitude, and list sweeps with customizable parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Stability Reference\u003c\/strong\u003e: Internal timebase with ≤ ±0.2 ppm\/year aging rate for long-term stability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Function Generator\u003c\/strong\u003e: Built-in 50 MHz arbitrary waveform generation for added versatility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Connectivity\u003c\/strong\u003e: Remote operation via LAN, USB, and optional GPIB interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStrategic Application Areas\u003c\/h2\u003e\n\u003ch3\u003eMillimeter-Wave Development and Pre-Compliance Testing\u003c\/h3\u003e\n\u003cp\u003eProvide fundamental signals for millimeter-wave system development, 5G FR2 testing, and automotive radar applications. The extended frequency range to 22 GHz serves as an ideal source for harmonic multiplication into mmWave bands up to 110 GHz.\u003c\/p\u003e\n\u003ch3\u003eAdvanced Wireless Communications Research\u003c\/h3\u003e\n\u003cp\u003eSupport development of cutting-edge wireless technologies including 5G NR, WiFi 6E, and emerging standards with clean, stable signals. The exceptional phase noise performance ensures accurate characterization of sensitive receivers.\u003c\/p\u003e\n\u003ch3\u003eSatellite Communications Systems\u003c\/h3\u003e\n\u003cp\u003eTest and validate satellite transponders, receivers, and ground station equipment with precise, stable signals. The extended frequency range covers crucial satellite bands including Ku, K, and Ka.\u003c\/p\u003e\n\u003ch3\u003eAerospace and Defense Systems\u003c\/h3\u003e\n\u003cp\u003eMeet stringent requirements for radar system development, electronic warfare applications, and secure communications testing. The superior performance characteristics ensure accurate characterization of mission-critical systems.\u003c\/p\u003e\n\u003ch3\u003eHigh-Frequency Component Testing\u003c\/h3\u003e\n\u003cp\u003eCharacterize filters, amplifiers, mixers, and integrated circuits operating at microwave and millimeter-wave frequencies with clean, stable test signals. The high output power eliminates the need for external amplifiers in many test scenarios.\u003c\/p\u003e\n\u003ch2\u003eComprehensive Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Offset\u003c\/td\u003e\n\u003ctd\u003eStep of 0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Attenuator\u003c\/td\u003e\n\u003ctd\u003e0 to 110 dB, 10 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Level Range\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +23 dBm (frequency dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.7 dB (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (1 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (10 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-102 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (22 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-98 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -40 dBc (9 kHz to 250 MHz), ≤ -50 dBc (250 MHz to 1 GHz), ≤ -40 dBc (1 GHz to 7.5 GHz), ≤ -35 dBc (7.5 GHz to 22 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-harmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -60 dBc (5 MHz to 750 MHz), ≤ -65 dBc (750 MHz to 7.5 GHz), ≤ -60 dBc (7.5 GHz to 14 GHz), ≤ -55 dBc (14 GHz to 22 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics\u003c\/td\u003e\n\u003ctd\u003eNone (9 kHz to 15 GHz), -70 dBc (15 GHz to 22 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Types\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (standard); Pulse (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-inch capacitive multi-touch screen (800×480)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eLAN (10\/100\/1000 Base, RJ-45), USB Device, USB Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Interfaces\u003c\/td\u003e\n\u003ctd\u003eGPIB (IEEE-488.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 (compatible with SMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC, 50\/60 Hz, \u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×L)\u003c\/td\u003e\n\u003ctd\u003e449mm × 100mm × 474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Period\u003c\/td\u003e\n\u003ctd\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMaximum Output Power Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003cth\u003eMaximum Output Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 kHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 250 MHz\u003c\/td\u003e\n\u003ctd\u003e+17 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;250 MHz to 3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;3.6 GHz to 7.5 GHz\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;7.5 GHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;14 GHz to 22 GHz\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAdvanced Functional Capabilities\u003c\/h2\u003e\n\u003ch3\u003eMechanical Attenuation System\u003c\/h3\u003e\n\u003cp\u003eThe USG5022M-P features a state-of-the-art mechanical attenuator system that provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuperior output power stability for the most demanding measurements\u003c\/li\u003e\n\u003cli\u003eEnhanced maximum output power up to +23 dBm (250 MHz to 3.6 GHz)\u003c\/li\u003e\n\u003cli\u003eHigh-precision 10 dB step attenuator with range from 0 to 110 dB\u003c\/li\u003e\n\u003cli\u003eOptimized standing wave ratio (SWR) performance across the entire frequency range\u003c\/li\u003e\n\u003cli\u003eExceptional long-term stability for mission-critical applications and production testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe mechanical attenuator delivers excellent VSWR performance and greater power stability compared to electronic attenuators, particularly important for extended frequency range applications up to 22 GHz. This results in more accurate power delivery and consistent measurements for high-frequency testing, millimeter-wave research, and advanced wireless development.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Sweep Functionality\u003c\/h3\u003e\n\u003cp\u003ePerform thorough device characterization with multiple sweep modes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear and logarithmic frequency sweeps for analyzing frequency response\u003c\/li\u003e\n\u003cli\u003eAmplitude sweeps for gain compression and linearity measurements\u003c\/li\u003e\n\u003cli\u003eList sweeps with up to 500 user-defined points for custom test sequences\u003c\/li\u003e\n\u003cli\u003eMultiple triggering options: auto, key, external, and bus triggers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVersatile Modulation Capabilities\u003c\/h3\u003e\n\u003cp\u003eGenerate sophisticated test signals with advanced modulation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAM with depth up to 99% and 0.1% resolution for envelope testing\u003c\/li\u003e\n\u003cli\u003eFM with maximum deviation up to N × 10 MHz for wideband applications\u003c\/li\u003e\n\u003cli\u003eΦM with maximum deviation up to N × 5 radians for phase modulation testing\u003c\/li\u003e\n\u003cli\u003eMultiple modulation sources: internal, external, or combined for complex signal creation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Pulse Modulation (USG5000M-PM)\u003c\/h3\u003e\n\u003cp\u003eAdd specialized pulse capabilities for radar and burst transmission testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-off ratio up to 80 dB (≤ 6.5 GHz) and 70 dB (≤ 22 GHz) for clean pulse generation\u003c\/li\u003e\n\u003cli\u003eRising\/falling times \u0026lt; 20 ns (typical) for precise edge transitions\u003c\/li\u003e\n\u003cli\u003eMultiple pulse modes: free-run, square, triggered, doublet, gated, and external\u003c\/li\u003e\n\u003cli\u003eCustomizable pulse trains for complex signal patterns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Narrow Pulse Generator (USG5000M-PG)\u003c\/h3\u003e\n\u003cp\u003eSupport advanced radar and high-speed digital testing with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum pulse width of 20 ns with 10 ns resolution for precise timing control\u003c\/li\u003e\n\u003cli\u003ePulse period from 40 ns to 42 s for flexible test configurations\u003c\/li\u003e\n\u003cli\u003eIdeal for automotive millimeter-wave radar system development and testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Comparison: USG5000M Series\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG5014M\u003c\/th\u003e\n\u003cth\u003eUSG5014M-P\u003c\/th\u003e\n\u003cth\u003eUSG5022M-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Attenuator\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (250 MHz to 3.6 GHz)\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (3.6 GHz to 7.5 GHz)\u003c\/td\u003e\n\u003ctd\u003e+15 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003ctd\u003e+12 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (14 GHz to 22 GHz)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics (15 GHz to 22 GHz)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-70 dBc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eUSG5022M-P vs. USG3000M Series Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG3065M-P (Top USG3000M)\u003c\/th\u003e\n\u003cth\u003eUSG5022M-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Frequency\u003c\/td\u003e\n\u003ctd\u003e6.5 GHz\u003c\/td\u003e\n\u003ctd\u003e22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eN-type female\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power (250 MHz to 1.2 GHz)\u003c\/td\u003e\n\u003ctd\u003e+24 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (1 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz (typical)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone (to 15 GHz), -70 dBc (15-22 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e426mm×88mm×400mm\u003c\/td\u003e\n\u003ctd\u003e449mm×100mm×474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 W\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003ePremium Accessories and Enhancements\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eOrder No.\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Modulation\u003c\/td\u003e\n\u003ctd\u003eAdds comprehensive pulse modulation capabilities\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNarrow Pulse Generator\u003c\/td\u003e\n\u003ctd\u003eEnables generation of narrow pulses for specialized testing\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Meter Kit\u003c\/td\u003e\n\u003ctd\u003eProvides power measurement, calibration, and control functions\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPIB Interface\u003c\/td\u003e\n\u003ctd\u003eAdds IEEE-488.2 connectivity for automated test systems\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Kit\u003c\/td\u003e\n\u003ctd\u003eComplete set of premium cables, adapters, and connectors\u003c\/td\u003e\n\u003ctd\u003eUT-CK02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Cable\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz-2.92J RF cable for high-frequency connections\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapters\u003c\/td\u003e\n\u003ctd\u003e2.92-KKG connectors and SMA-N adapters for flexibility\u003c\/td\u003e\n\u003ctd\u003eUT-C04-40GHz, UT-C03-18GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eStandard Package Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5022M-P RF Signal Generator\u003c\/li\u003e\n\u003cli\u003ePower cord (compliant with local standards)\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003e2.92-KKG connector (UT-C04-40GHz)\u003c\/li\u003e\n\u003cli\u003eComprehensive user manual\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eUNI-T guarantees the USG5022M-P against defects in materials and workmanship for three years from purchase. Accessories are covered by a one-year warranty.\u003c\/p\u003e\n\u003cp\u003eRegular calibration is recommended every 12 months to maintain optimal performance and measurement accuracy.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the UNI-T USG5022M-P?\u003c\/h2\u003e\n\u003cp\u003eThe USG5022M-P represents the pinnacle of UNI-T's signal generation technology, offering exceptional performance at a competitive price point. With its extended frequency range to 22 GHz, mechanical attenuator for enhanced output power, and comprehensive feature set, this premium instrument addresses the most demanding requirements in advanced RF and microwave testing.\u003c\/p\u003e\n\u003cp\u003eWhether you're developing next-generation wireless technologies, characterizing high-frequency components, or conducting cutting-edge research, the USG5022M-P delivers the performance, reliability, and versatility needed for success.\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103321817372,"sku":"181300200009X","price":24899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5022M_F-S.png?v=1740667870"},{"product_id":"usg5014m-p-analog-rf-gen-atten","title":"USG5014M-P 14GHz Analog RF Generator with Attenuator","description":"\u003ch1\u003eUNI-T USG5014M-P RF Signal Generator with Mechanical Attenuator\u003c\/h1\u003e\n\u003ch2\u003ePremium Microwave Signal Generation to 14 GHz with Enhanced Output Power\u003c\/h2\u003e\n\u003cp\u003eThe UNI-T USG5014M-P delivers professional-grade signal generation from 9 kHz to 14 GHz with the superior performance of mechanical attenuation for enhanced output power capabilities. This high-performance instrument combines extended frequency coverage, exceptional signal purity, and premium output stability to meet the most demanding requirements in advanced RF and microwave testing applications.\u003c\/p\u003e\n\u003ch2\u003eElite Performance Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Attenuator System\u003c\/strong\u003e: Premium mechanical attenuation for superior output power stability and enhanced signal integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Microwave Coverage\u003c\/strong\u003e: Generate precision signals from 9 kHz to 14 GHz with 0.001 Hz resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Output Power\u003c\/strong\u003e: Deliver up to +23 dBm (250 MHz to 3.6 GHz) for driving power-hungry devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Dynamic Range\u003c\/strong\u003e: Set levels from -135 dBm to +23 dBm with 0.01 dB resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePristine Signal Quality\u003c\/strong\u003e: Ultra-low phase noise (\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Modulation\u003c\/strong\u003e: Standard AM, FM, and ΦM capabilities with multiple configuration options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Sweep Functions\u003c\/strong\u003e: Frequency, amplitude, and list sweeps with customizable parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePremium Reference Stability\u003c\/strong\u003e: Internal timebase with ≤ ±0.2 ppm\/year aging rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in 50 MHz Function Generator\u003c\/strong\u003e: Integrated arbitrary waveform generation capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModern Connectivity\u003c\/strong\u003e: Remote operation via LAN, USB, and optional GPIB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecialized Application Domains\u003c\/h2\u003e\n\u003ch3\u003eAdvanced Wireless Development and Testing\u003c\/h3\u003e\n\u003cp\u003eSupport development of 5G, WiFi 6E, and next-generation wireless technologies with clean, powerful signals. The mechanical attenuator provides the stability and output power needed for comprehensive receiver testing and component characterization.\u003c\/p\u003e\n\u003ch3\u003eAerospace and Defense Applications\u003c\/h3\u003e\n\u003cp\u003eMeet the stringent requirements of radar system development, satellite communications, and electronic warfare with high-quality signals and precise level control. The superior performance characteristics ensure accurate testing of sensitive aerospace components.\u003c\/p\u003e\n\u003ch3\u003eSemiconductor and Component Characterization\u003c\/h3\u003e\n\u003cp\u003eTest high-frequency RF components, filters, amplifiers, and integrated circuits with stable, accurate signals at the required power levels. The mechanical attenuator eliminates the need for external amplifiers in many test scenarios.\u003c\/p\u003e\n\u003ch3\u003eMillimeter-Wave System Development\u003c\/h3\u003e\n\u003cp\u003eProvide fundamental signals for frequency multiplication to mmWave bands with excellent spectral purity. The 14 GHz coverage serves as an ideal foundation for extending into millimeter-wave frequencies.\u003c\/p\u003e\n\u003ch3\u003eHigh-Performance Production Testing\u003c\/h3\u003e\n\u003cp\u003eIntegrate into automated test systems for reliable, repeatable measurements in manufacturing environments. The mechanical attenuator ensures long-term stability for continuous operation in production settings.\u003c\/p\u003e\n\u003ch2\u003eDetailed Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Offset\u003c\/td\u003e\n\u003ctd\u003eStep of 0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Attenuator\u003c\/td\u003e\n\u003ctd\u003e0 to 110 dB, 10 dB step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Level Range\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +23 dBm (frequency dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.7 dB (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (1 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (10 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-102 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -40 dBc (9 kHz to 250 MHz), ≤ -50 dBc (250 MHz to 1 GHz), ≤ -40 dBc (1 GHz to 7.5 GHz), ≤ -35 dBc (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-harmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -60 dBc (5 MHz to 750 MHz), ≤ -65 dBc (750 MHz to 7.5 GHz), ≤ -60 dBc (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics\u003c\/td\u003e\n\u003ctd\u003eNone (9 kHz to 15 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Types\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (standard); Pulse (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-inch capacitive multi-touch screen (800×480)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eLAN (10\/100\/1000 Base, RJ-45), USB Device, USB Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Interfaces\u003c\/td\u003e\n\u003ctd\u003eGPIB (IEEE-488.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 (compatible with SMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC, 50\/60 Hz, \u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×L)\u003c\/td\u003e\n\u003ctd\u003e449mm × 100mm × 474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Period\u003c\/td\u003e\n\u003ctd\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMaximum Output Power Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003cth\u003eMaximum Output Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 kHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 250 MHz\u003c\/td\u003e\n\u003ctd\u003e+17 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;250 MHz to 3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;3.6 GHz to 7.5 GHz\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;7.5 GHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear and logarithmic frequency sweeps for comprehensive response analysis\u003c\/li\u003e\n\u003cli\u003eAmplitude sweeps for gain compression and linearity testing\u003c\/li\u003e\n\u003cli\u003eList sweeps with up to 500 user-defined points for custom test sequences\u003c\/li\u003e\n\u003cli\u003eMultiple triggering options: auto, key, external, and bus triggers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSophisticated Modulation Options\u003c\/h3\u003e\n\u003cp\u003eCreate complex test signals with advanced modulation features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAM with depth up to 99% and 0.1% resolution for envelope testing\u003c\/li\u003e\n\u003cli\u003eFM with maximum deviation up to N × 10 MHz for wideband applications\u003c\/li\u003e\n\u003cli\u003eΦM with maximum deviation up to N × 5 radians for phase-sensitive testing\u003c\/li\u003e\n\u003cli\u003eMultiple source options: internal, external, or combined modulation sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Pulse Modulation (USG5000M-PM)\u003c\/h3\u003e\n\u003cp\u003eEnhance testing capabilities with specialized pulse modulation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-off ratio up to 80 dB (≤ 6.5 GHz) and 70 dB (≤ 22 GHz) for clean pulse generation\u003c\/li\u003e\n\u003cli\u003eRising\/falling times \u0026lt; 20 ns (typical) for fast edge transitions\u003c\/li\u003e\n\u003cli\u003eMultiple pulse modes: free-run, square, triggered, doublet, gated, external\u003c\/li\u003e\n\u003cli\u003eCustomizable pulse trains for complex signal patterns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Narrow Pulse Generator (USG5000M-PG)\u003c\/h3\u003e\n\u003cp\u003eSupport advanced radar and high-speed digital testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum pulse width of 20 ns with 10 ns resolution for precise timing control\u003c\/li\u003e\n\u003cli\u003ePulse period from 40 ns to 42 s for flexible test configurations\u003c\/li\u003e\n\u003cli\u003eIdeal for automotive millimeter-wave radar system development and testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Comparison: USG5000M Series\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG5014M\u003c\/th\u003e\n\u003cth\u003eUSG5014M-P\u003c\/th\u003e\n\u003cth\u003eUSG5022M-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Attenuator\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (250 MHz to 3.6 GHz)\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (3.6 GHz to 7.5 GHz)\u003c\/td\u003e\n\u003ctd\u003e+15 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003ctd\u003e+12 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (14 GHz to 22 GHz)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eUSG5014M-P vs. USG3000M Series Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG3065M-P (Top USG3000M)\u003c\/th\u003e\n\u003cth\u003eUSG5014M-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Frequency\u003c\/td\u003e\n\u003ctd\u003e6.5 GHz\u003c\/td\u003e\n\u003ctd\u003e14 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eN-type female\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power (250 MHz to 1.2 GHz)\u003c\/td\u003e\n\u003ctd\u003e+24 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e426mm×88mm×400mm\u003c\/td\u003e\n\u003ctd\u003e449mm×100mm×474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 W\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOptional Accessories and Enhancements\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eOrder No.\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Modulation\u003c\/td\u003e\n\u003ctd\u003eAdds pulse modulation capability for radar testing\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNarrow Pulse Generator\u003c\/td\u003e\n\u003ctd\u003eEnables generation of narrow pulses for specialized applications\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Meter Kit\u003c\/td\u003e\n\u003ctd\u003eProvides power measurement, calibration, and control functions\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPIB Interface\u003c\/td\u003e\n\u003ctd\u003eAdds IEEE-488.2 connectivity for automated test systems\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Kit\u003c\/td\u003e\n\u003ctd\u003eComprehensive set of cables, adapters, and connectors\u003c\/td\u003e\n\u003ctd\u003eUT-CK02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Cable\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz-2.92J RF cable for microwave connections\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003e2.92-KKG connector for interface compatibility\u003c\/td\u003e\n\u003ctd\u003eUT-C04-40GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003eRF adapter SMA-N for connection flexibility\u003c\/td\u003e\n\u003ctd\u003eUT-C03-18GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eStandard Package Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M-P RF Signal Generator\u003c\/li\u003e\n\u003cli\u003ePower cord (compliant with local standards)\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003e2.92-KKG connector (UT-C04-40GHz)\u003c\/li\u003e\n\u003cli\u003eComprehensive user manual\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eUNI-T provides a three-year warranty against defects in materials and workmanship for the USG5014M-P. Accessories are covered by a one-year warranty.\u003c\/p\u003e\n\u003cp\u003eRegular calibration is recommended every 12 months to maintain optimal performance and measurement accuracy.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the UNI-T USG5014M-P?\u003c\/h2\u003e\n\u003cp\u003eThe USG5014M-P represents an optimal balance of advanced frequency coverage, superior output power, and exceptional signal quality for demanding RF and microwave applications. The mechanical attenuator provides the stability and higher power levels required for testing power amplifiers, receiver sensitivity, and other applications where signal strength and stability are critical.\u003c\/p\u003e\n\u003cp\u003eFor applications requiring frequencies beyond 14 GHz, consider the USG5022M-P, which extends coverage to 22 GHz while maintaining the same premium features and output capabilities.\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103322177820,"sku":"181300200012X","price":21899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5022M_F-S.png?v=1740667870"},{"product_id":"usg5014m-analog-rf-gen","title":"USG5014M 14GHz Analog RF Generator","description":"\u003ch1\u003eUNI-T USG5014M RF Signal Generator\u003c\/h1\u003e\n\u003ch2\u003eAdvanced RF Signal Generation to 14 GHz with Exceptional Performance\u003c\/h2\u003e\n\u003cp\u003eThe USG5014M represents UNI-T's commitment to delivering professional-grade RF signal generation for the most demanding applications. With frequency coverage from 9 kHz to 14 GHz and exceptional signal purity, this advanced instrument meets the needs of wireless communications development, aerospace engineering, and semiconductor testing where extended frequency range and superior performance are essential.\u003c\/p\u003e\n\u003ch2\u003eCutting-Edge Performance Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Frequency Range\u003c\/strong\u003e: Generate precise signals from 9 kHz to 14 GHz with 0.001 Hz resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Output Power Range\u003c\/strong\u003e: Set levels from -135 dBm to +18 dBm with 0.01 dB resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExceptional Signal Purity\u003c\/strong\u003e: Ultra-low phase noise (\u0026lt;-122 dBc\/Hz @ 1 GHz, 20 kHz offset)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Attenuator\u003c\/strong\u003e: Fast, reliable level control across the full frequency range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Modulation\u003c\/strong\u003e: Standard AM, FM, and ΦM capabilities with flexible configuration options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Sweep Modes\u003c\/strong\u003e: Frequency, amplitude, and list sweeps with user-defined parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Stability Reference\u003c\/strong\u003e: Internal reference with ≤ ±0.2 ppm\/year aging rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated 50 MHz Function Generator\u003c\/strong\u003e: Built-in arbitrary waveform generation capabilities\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModern Connectivity\u003c\/strong\u003e: Remote control via LAN and USB interfaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntuitive Touch Interface\u003c\/strong\u003e: 5-inch capacitive touchscreen with clear visual workflow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Attenuator\u003c\/strong\u003e: Enhanced output power and superior level stability (-P Model Only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecialized Applications\u003c\/h2\u003e\n\u003ch3\u003eAdvanced Wireless Communications\u003c\/h3\u003e\n\u003cp\u003eSupport development and testing of next-generation wireless technologies including 5G, WiFi 6E, and emerging standards. The extended frequency range covers critical bands for cellular, WiFi, Bluetooth, and IoT communications.\u003c\/p\u003e\n\u003ch3\u003eAerospace and Defense Systems\u003c\/h3\u003e\n\u003cp\u003eProvide precision signals for radar system development, satellite communications, and electronic warfare applications. The exceptional phase noise performance enables accurate characterization of sensitive receivers.\u003c\/p\u003e\n\u003ch3\u003eMillimeter-Wave Development\u003c\/h3\u003e\n\u003cp\u003eFacilitate pre-compliance testing and development of millimeter-wave components and systems. The 14 GHz capability serves as a fundamental signal source for frequency multiplication to higher bands.\u003c\/p\u003e\n\u003ch3\u003eSemiconductor Testing\u003c\/h3\u003e\n\u003cp\u003eCharacterize high-frequency RF components, filters, amplifiers, and integrated circuits with clean, stable test signals. The wide frequency range eliminates the need for multiple instruments in many test setups.\u003c\/p\u003e\n\u003ch3\u003eResearch and Education\u003c\/h3\u003e\n\u003cp\u003eSupport advanced RF research and education with a versatile, high-performance signal source. The comprehensive feature set accommodates diverse experimental requirements in university and research laboratory environments.\u003c\/p\u003e\n\u003ch2\u003eDetailed Technical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Offset\u003c\/td\u003e\n\u003ctd\u003eStep of 0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Level Range\u003c\/td\u003e\n\u003ctd\u003e-135 dBm to +18 dBm (frequency dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.7 dB (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (1 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-122 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (10 GHz, 20 kHz offset)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;-102 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -40 dBc (9 kHz to 250 MHz), ≤ -50 dBc (250 MHz to 1 GHz), ≤ -40 dBc (1 GHz to 7.5 GHz), ≤ -35 dBc (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-harmonics\u003c\/td\u003e\n\u003ctd\u003e≤ -60 dBc (5 MHz to 750 MHz), ≤ -65 dBc (750 MHz to 7.5 GHz), ≤ -60 dBc (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics\u003c\/td\u003e\n\u003ctd\u003eNone (9 kHz to 15 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Types\u003c\/td\u003e\n\u003ctd\u003eAM, FM, ΦM (standard); Pulse (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-inch capacitive multi-touch screen (800×480)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eLAN (10\/100\/1000 Base, RJ-45), USB Device, USB Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Interfaces\u003c\/td\u003e\n\u003ctd\u003eGPIB (IEEE-488.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92 (compatible with SMA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC, 50\/60 Hz, \u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×L)\u003c\/td\u003e\n\u003ctd\u003e449mm × 100mm × 474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Period\u003c\/td\u003e\n\u003ctd\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMaximum Output Power Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Range\u003c\/th\u003e\n\u003cth\u003eMaximum Output Power\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e9 kHz to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e+13 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;5 MHz to 250 MHz\u003c\/td\u003e\n\u003ctd\u003e+14 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;250 MHz to 3.6 GHz\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;3.6 GHz to 7.5 GHz\u003c\/td\u003e\n\u003ctd\u003e+15 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u0026gt;7.5 GHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e+12 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAdvanced Capabilities\u003c\/h2\u003e\n\u003ch3\u003eComprehensive Sweep Functionality\u003c\/h3\u003e\n\u003cp\u003eCreate thorough device characterizations with multiple sweep options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear and logarithmic frequency sweeps\u003c\/li\u003e\n\u003cli\u003eStepped and continuous amplitude sweeps\u003c\/li\u003e\n\u003cli\u003eUser-defined list sweeps with up to 500 points\u003c\/li\u003e\n\u003cli\u003eMultiple triggering options: auto, key, external, and bus triggers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVersatile Modulation Capabilities\u003c\/h3\u003e\n\u003cp\u003eGenerate sophisticated test signals with advanced modulation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAM with depth up to 99% and 0.1% resolution\u003c\/li\u003e\n\u003cli\u003eFM with maximum deviation up to N × 10 MHz\u003c\/li\u003e\n\u003cli\u003eΦM with maximum deviation up to N × 5 radians\u003c\/li\u003e\n\u003cli\u003eMultiple modulation sources: internal, external, or combined\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Pulse Modulation (USG5000M-PM)\u003c\/h3\u003e\n\u003cp\u003eEnhance testing capabilities with specialized pulse functionality:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOn-off ratio up to 80 dB (≤ 6.5 GHz) and 70 dB (≤ 22 GHz)\u003c\/li\u003e\n\u003cli\u003eRising\/falling times \u0026lt; 20 ns (typical)\u003c\/li\u003e\n\u003cli\u003eMultiple pulse modes: free-run, triggered, doublet, gated\u003c\/li\u003e\n\u003cli\u003eCustomizable pulse trains for complex signal simulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional Narrow Pulse Generator (USG5000M-PG)\u003c\/h3\u003e\n\u003cp\u003eSupport advanced radar testing with specialized pulse capabilities:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum pulse width of 20 ns with 10 ns resolution\u003c\/li\u003e\n\u003cli\u003ePulse period from 40 ns to 42 s\u003c\/li\u003e\n\u003cli\u003eIdeal for automotive millimeter-wave radar testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eModel Comparison: USG5000M Series\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG5014M\u003c\/th\u003e\n\u003cth\u003eUSG5014M-P\u003c\/th\u003e\n\u003cth\u003eUSG5022M-P\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 14 GHz\u003c\/td\u003e\n\u003ctd\u003e9 kHz to 22 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Attenuator\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (250 MHz to 3.6 GHz)\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003ctd\u003e+23 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (3.6 GHz to 7.5 GHz)\u003c\/td\u003e\n\u003ctd\u003e+15 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003ctd\u003e+20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (7.5 GHz to 14 GHz)\u003c\/td\u003e\n\u003ctd\u003e+12 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003ctd\u003e+18 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power (14 GHz to 22 GHz)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e+16 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eUSG5014M vs. USG3000M Series Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUSG3000M Series\u003c\/th\u003e\n\u003cth\u003eUSG5014M\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Frequency\u003c\/td\u003e\n\u003ctd\u003e4.5 GHz \/ 6.5 GHz\u003c\/td\u003e\n\u003ctd\u003e14 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Output Connector\u003c\/td\u003e\n\u003ctd\u003eN-type female\u003c\/td\u003e\n\u003ctd\u003eNMD 2.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Noise (10 GHz)\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e-102 dBc\/Hz (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-harmonics (to max freq)\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e426mm×88mm×400mm\u003c\/td\u003e\n\u003ctd\u003e449mm×100mm×474mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;50 W\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eOptional Accessories and Enhancements\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eOrder No.\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Modulation\u003c\/td\u003e\n\u003ctd\u003eAdds comprehensive pulse modulation capabilities\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNarrow Pulse Generator\u003c\/td\u003e\n\u003ctd\u003eEnables generation of narrow pulses for specialized testing\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Meter Kit\u003c\/td\u003e\n\u003ctd\u003eProvides power measurement, calibration, and control\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPIB Interface\u003c\/td\u003e\n\u003ctd\u003eAdds IEEE-488.2 connectivity for system integration\u003c\/td\u003e\n\u003ctd\u003eUSG5000M-GPIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Kit\u003c\/td\u003e\n\u003ctd\u003eComprehensive set of cables, adapters, and connectors\u003c\/td\u003e\n\u003ctd\u003eUT-CK02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF Cable\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz-2.92J RF cable\u003c\/td\u003e\n\u003ctd\u003eUT-W03-40GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003e2.92-KKG connector\u003c\/td\u003e\n\u003ctd\u003eUT-C04-40GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003eRF adapter SMA-N\u003c\/td\u003e\n\u003ctd\u003eUT-C03-18GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eStandard Package Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUSG5014M RF Signal Generator\u003c\/li\u003e\n\u003cli\u003ePower cord (compliant with local standards)\u003c\/li\u003e\n\u003cli\u003eUSB data cable (UT-D14)\u003c\/li\u003e\n\u003cli\u003e2.92-KKG connector (UT-C04-40GHz)\u003c\/li\u003e\n\u003cli\u003eComprehensive user manual\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003c\/li\u003e\n\u003cli\u003eQuick start guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWarranty Information\u003c\/h2\u003e\n\u003cp\u003eUNI-T guarantees the USG5014M against defects in materials and workmanship for three years from purchase date. Accessories are covered by a one-year warranty.\u003c\/p\u003e\n\u003cp\u003eRegular calibration is recommended every 12 months to maintain optimal performance and measurement accuracy.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the UNI-T USG5014M?\u003c\/h2\u003e\n\u003cp\u003eThe USG5014M delivers exceptional performance and extended frequency coverage at a competitive price point. Its 14 GHz capability addresses the needs of modern wireless communications, aerospace, defense, and research applications without the premium cost of higher-frequency instruments.\u003c\/p\u003e\n\u003cp\u003eFor applications requiring higher output power, consider the USG5014M-P with mechanical attenuator. For frequencies beyond 14 GHz, the USG5022M-P extends coverage to 22 GHz while maintaining all the premium features and benefits of the USG5000M series.\u003c\/p\u003e","brand":"Uni-T","offers":[{"title":"Default Title","offer_id":51103322341660,"sku":"181300200016X","price":16899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/files\/USG5022M_F-S.png?v=1740667870"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0822\/9208\/0924\/collections\/USG5022M_1.jpg?v=1741116533","url":"https:\/\/uni-trendus.com\/collections\/usg5000m.oembed","provider":"Uni-Trend US","version":"1.0","type":"link"}